The outstanding precision and reliability of the haze meter, as well as its ease of use, have made the haze meter the standard for transparency measurement in the glass, plastic, film and packaging industries.
Optimize Surface Quality with Advanced Haze Meters
3nh Color Haze Meter can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, haze test, clarity test.With the precision concave grating and 256 pixel CMOS detector, it can accurately collect the transmittance curve of the transmitted sample, accurately output the various chromaticity data of the transmitted sample, and realize the high precision and repeatable measurement of the transmittance, haze and chromaticity data.
3nh YH1810 Color Haze Meter can easily realize ASTM D1003 non- compensation method,ISO 13468compensation method, full light transmittance, haze test,clarity test.With the precision concave grating and 256 pixel CMOS detector, it can accurately collect the transmittance curve of the transmitted sample, accurately output the various chromaticity data of the transmitted sample, and realize the high precision and repeatable measurement of the transmittance, haze and chromaticity data.
The instrument can easily implement ASTM D1003 non-compensation method, ISO 13468compensation method, total transmittance, haze test, and clarity test.
The hardware configuration is high, the measurement area is open, and the vertical and horizontal tests can be performed.
A variety of measuring fixtures help you easily measure various samples
FAQs About Haze Meters
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.