Order No. | Name | Model | D65 | TL84/U30 | F/A | UV | CWF | Voltage |
10103 | Standard light source box | M60 five light source(220V) | 2 pcs | 1 pcs | 4 pcs | 1 pcs | 1 pcs | 220V/50Hz |
10803 | Standard light source box | M60 five light source(115V) | 2 pcs | 1 pcs | 4 pcs | 1 pcs | 1 pcs | 115V/60Hz |
Light Source | Color viewing booths application | Color temperature(k) | Power(W) | Brand&Specification |
D65 | International standard Artificial Daylight | 6500 | 20 | Gretagmacbeth F20T12/65 |
TL84 | Applied to stores in EuropeJapan and China | 4000 | 18 |
PHILIPS TLD 18W/840 |
CWF | (Cool White Fluorescent)American Standard | 4150 | 18 |
SYLVANIA F20T12/CW |
TL83 | Warm White Fluorescent American Standard | 3000 | 18 |
PHILIPS TLD 18W/830 |
F | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
3nh 40W |
A | American shopwindow spotlight | 2700 | 40 |
3nh 60W |
UV | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wavelength:365nm | 20 |
PHILIPS TLD 18W/BLB |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
Our professional team will give you the best suggestion as long as you tell us what kind of test you need to do and the required specification.
At most of time, we have Spectrophotometer stock in the factory. Generally it is 1-3 working days after the payment confirmed. After shipped, we will email you the tracking number. You can check the shipping status of your order on the website. If you are in urgent need, we can consider making special arrangement for you.
Inquiry - quotation - communication - order confirming - deposit payment - production - testing and debugging - balance payment - packing - delivery - customer receiving - after service.
SCI&SCE are two method in the color measurement. SCI means Specular Component Include,SCE means Specular Component Exclude.
Under the method of SCE, only test diffuse refection and exclude specular reflection. In that way, the test result is similar to object color was observed by human eyes.
Under the method SCI, both the diffuse refection and specular reflection will be included. In that way, the value about the color is more objective. It will not effect by the environment condition.
When we choose the instrument, those elements should be taking into consideration.
Colorimeter,Gloss meter,Coating thickness meter,window tint meter,UV meter, Leeb hardness tester, Ultrasonic thickness gauge. Threenh Technology company adheres to independent design, research and development, production and sales of various measuring instruments.