Multi-angle spectrophotometer MS3005
The MS3005 Multi-angle Spectrophotometer is a device for color measurement, adopts Industrial-grade MCU with 5 measuring angles, which can provide accurate and consistent color measurement for metalllics, pearlescents and other complex special effect finished products. It is mainly used to measure the color difference of surface paint affected by different viewing angles and conditions.
Key Highlights
5 measurement angles
256-image element double-array CMOS image sensor
3.5-inch LCD Capacitive Touch Screen
Full spectrum LED light source
Excellent agreement between instruments ΔE*<0.20
Φ23mm Measuring Aperture
Widely applicable to industries such as coatings, paints, automobiles, cosmetics, inks, etc
3nh Multi-angle spectrophotometer MS3005 is used to measure the color difference for the surface paint which is affected by different viewing angles and viewing conditions. It can provide accurate and consistent color measurement for metalllics, pearlescents and other complex special effect finished products.
MS3005 multi-angle spectrophotometer adopts industrial-grade MCU and is equipped with 5 measuring angles, under the superior performance of the optical measurement system supported by MS3005 multi-angle spectrophotometer has excellent performance in multi-angle chromatic aberration measurement, even in the curved surface, but also has a high measurement accuracy and stability.
Technical characteristics
Adopt 5 illumination sources, 1 receivers to measure 5 measurement angles at the same time
Touch screen can display all Angle measurement results, more intuitive view of the comprehensive data.
Quickly distinguish the sample Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV), simple and effective quality inspection.
The higher optical resolution ensures the measuring speed, accuracy, stability and consistency of the instrument. The core technology makes it as the same platform with international standards and complete compatibility.
The Full spectrum LED light source with blue enhancement ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of LED in a specific band, and ensures the accuracy of instrument measurement results and low cost maintenance.
Using concave grating spectrophotometric technology, with higher resolution, makes color measurement more accurate.
Professional-grade white board, high hardness in the surface, stable optical performance
Industrial grade real-time processing MCU, Bluetooth 5.0 transferring more stable and reliable.
The instrument appearance design is easy to operate, and the hand holding position and the measurement button are well-designed, which can meet different holding habits, smooth and fine surface, from the high-precision appearance treatment process.
Built-in color camera positioning, can accurately judge the object measured position, and improve the measurement efficiency and accuracy.
Offer CIE LAB,XYZ,Yxy,LCh,β XY,DIN Lab99 color space, And D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4 and F5, F6 and F7 (DLF), F8, F9, F10 (TPL5), and F11 (TL84), F12 (TL83/U30) A variety of light source, which can meet the special measurement demand under different measurement conditions.
The screen can intuitively display spectrum/data, sample chromaticity value, color difference value/figure, pass/fail results, color simulation, sample effect value, effect difference value and other data, convenient to view while also greatly improve the user's work efficiency.
Technical parameters
Model | MS3005 |
Measurement Geometry | 5 measurement angles (5 illumination sources, 1 receivers) |
Measure Angle |
45° Receiver: 45as15°,45as25°,45as45°,45as75°,45as110° Conform to the standards:ASTM D 2244,E 308,E 1164,E 2194, E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4 SAE J 1545 |
Application | Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products |
Light Source | Full spectrum LED light source with blue enhancement |
Lamp Life | 5 years, 3 million times measurements |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400nm-700nm |
Wavelength Interval | 10nm |
Measurement Range | 0~600% |
Semiband Width | 10nm |
Measuring Aperture | Illumination size Φ23mm / Measuring spot 9X12mm |
Color Space | CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE DIN6175 |
Other Colorimetric Index | Flop Index |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30) |
Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time |
Approx. 1 second for one angle Approx. 5 seconds for all angles |
Repeatability |
Spectral reflectance: Standard deviation within 0.08% Chromaticity value: ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Reproducibility |
ΔE*<0.10,avg on the gray tile of BCRA tile set ΔE*<0.25,avg on the color BCRA tile set |
Inter-instrument Error | 0.2ΔE*00(avg on reference Series II BCRA tile set) |
Effect Parameters | / |
Effect Measurement | / |
Effect Repeatability | / |
Effect Reproducibility | / |
Trigger mode | Pressure sensing trigger, button trigger, software trigger |
Measuring Mode | Single measurement, average measurement (1-99), continuous measurement (1-99) |
Locating Mode | Color camera preview |
Dimension | L*W*H=195X83X128mm |
Weight | About 1Kg |
Power | lithium-ion battery, 3.7V,5000mAh, Continuous test 6000 times within 8 hours of full charge |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, Bluetooth 5.0 |
Data Storage | 1000 pcs Standards,4000 pcs Samples |
Language | Simplified Chinese, Traditional Chinese, English |
Operating Environment | 10℃ to 50℃, humidity does not exceed 85%, no condensation |
Storage Environment | -20℃ to 50℃, humidity does not exceed 85%, no condensation |
Calibration | Built-in white board parameters, external white board, black light trap |
Calibration Interval | 4 hours,8 hours,24 hours,Startup calibration |
Standard accessories | Power Adapter, USB Cable, User Guide,PC Software(download from the official website), Calibration Board, black light trap,Protective cap, wristband |
Optional Accessory | Micro-printer |
Notes | Technical parameters are for reference only, subject to actual sales products. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Multi-angle spectrophotometer
Yes, we can offer quality certification issued by our lab free of charge, or issued by third-party international inspection Organizations with extra charge, please contact us for confirmation.
Threenh Technology colorimeter is shipped with an operating instructions and video of English version.If you need an electronic version of the user manual, you can download it from our website download center
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
a. Right click "! USB Device" or "! SCI USB2Serial (COM6)", "Update Driver" -> "Install from a list or specific location (Advanced)" -> "Next" ->"Include this location in the search" -> "Browse", specify USB driver file path "CQCS3USB_Driver", click "Next". Then it will install successfully.
b.Detailed installation information please refers to "2.2 Installing USB Driver" in Color Quality Management System User Manual.doc.