YH1200 Haze Meter

This YH1200 Haze Meter Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.

 

Technical Advantage

 

1.Double standard ISO & ASTM

Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136

2.Easy to operate, faster and more accurate measurement

The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.

3.Dynamic measurement

Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.

4.With compensation port, so that the measurement data more accurate

Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.

5.Easy to measure and widely applicable to samples

Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.

6.Quality control software

It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.

Application

YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.

 

Product Model  YH1200 Haze Meter
Optical Geometry Transmittance:0/D(Parallel light illumination, diffuse viewing)
Conforms to:ASTM D1003/1044,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
Character The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
Integrating Sphere Size Φ154mm
Light Source 400nm to 700nm, combined LED light
Specular Component /
Sensor The PD array detector satisfies CIE V(λ)2 degree visual response
Wavelength Range /
Wavelength Interval /
Semiband Width /
Transmittance measurement range 0~100%
Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)
Sample Size Thickness <170mm
Color Space /
Color Difference Formula /
Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM)
Observer Angle
Illuminant D65,A,C
Displayed Data PASS/FAIL Result
Measuring Time About1.5s
Haze resolution 0.01unit
Haze repeatability Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)
Inter-instrument Error Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)
Dimension L*W*H=290X211X511mm
Weight About7.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB & Print serial port
Data Storage Standard 1000 pcs,sample 20000 pcs
Language Simplified Chinese,Traditional Chinese,English
Operating Environment 0~40℃(32~104°F)
Storage Environment  -20~50℃(-4~122°F)
Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box,Aperture.
Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch
Note: The specifications are subject to change without notice.

12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

FAQs About Haze Meters

Always a pre-production sample before mass production; Always final Inspection before shipment; 

Since part of the light will pass through the light-transmitting materials, the colorimeter is not suitable for color measurement of such kinds of materials; however, when place a pure color material with uniform texture under the light-transmitting material, we can measure the color difference between the standard and the sample. 

You can choose a colorimters depending on the substrate you are measuring the color of, whether it is opaque, translucent or transparent. In short, you can consider the following factors for choosing the right 3NH colorimeter for your needs: Sample Opacity, Physical Form, Optical Properties needed, Measurement Methods required, Scales and Indices needed, Instrument Standards Conformance (ASTM/ISO/Other), Instrument Geometry, Instrument Performance, Location (laboratory, portability, in-process) and Sample Handling requirements.

By systematically addressing these factors, you can select a colorimeter that optimizes accuracy, efficiency, and value for your specific application.Learn more from our ultimate guide on colorimeter selection. If unsure, consult the 3NH manufacturer for personalized recommendations based on your sample and workflow.


a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

a. Connect colorimeter to the PC with USB cable.

b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.

c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".

d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".

Related Haze Meters You May Also Like