HG Series Touch Screen Gloss Meter HG268
HG series economic gloss meter is independently developed by 3nh, with independent intellectual property. Manufactured according to International standard ISO2813and Chinesestandard GB/T 9754,it is the world's first full large touch screen gloss meter.
Key Highlights
Large Touch Screen Operation, Fully Automatic Calibration
Tri-Angle 20°, 60°, 85° Test
Display 5 sets of measurement data
Ergonomic Design
One button for all angles measurement at the same location
Data Storage & Connectivity
Achieve precise gloss control with 3nh's cutting-edge portable gloss tester. Engineered for industrial applications, this compact instrument delivers instant, accurate readings for coatings, plastics, metals, and more.
Key features include:
Tri-Angle Technology (20°, 60°, 85°) for comprehensive surface analysis
High Precision compliant with ISO, ASTM, and DIN standards
Ultra-Fast Measurement (<1 second) for efficient quality control
Data Storage & Connectivity for seamless integration into workflows
Ergonomic Design for one-handed operation in field or lab settings
Trusted by industries worldwide, 3nh's gloss meters ensure consistency, reduce waste, and enhance product aesthetics. Ideal for automotive, aerospace, printing, and manufacturing.
HG268 gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with international standards of ASTM D523, ASTM D2457. HG268 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source.
HG268 gloss meter is widely used to test glossiness in these industries, such as automobile, paint, ink, stoving varnish, coating, wood products, marble, granite, vitrified polished tile, pottery brick and porcelain, plastic, paper; hardware industries, etc.
GQC6 Software Introduction:
GQC6 software is used with 3nh gloss meter for PC connection, measurement, data management, data export, print reports, etc.
HG268 Tri-angle Gloss Meter | |
Model: | HG268 |
Measuring Angle |
20°/60°/85° Comply with standard ISO 2813, GB/T 9754, ASTM D 523, ASTM D 2457 |
Measuring Area (mm) | 20°: 10x10 60°: 9x15 85°: 5x36 |
Measuring Range | 20°:0~1000GU 60°:0~1000GU 85°:0~160GU |
Division Value | 0.1GU |
Measurement Range Repeatability Reproducibility |
0-10GU 10-100GU 100-1000GU ± 0.1GU ± 0.2GU ± 0.2%GU ± 0.2GU ± 0.5GU ± 0.5%GU |
Measurement Standard | Conform with JJG696 first class glossmeter working requirement |
Chromaticity Corresponding | Corresponding with CIE 1931(2°) under CIE C light source |
Errors | ±1.5 , ± 1.5% |
Measuring Time | 0.1s |
Dimension | L*W*H : 160mm*75mm*90mm |
Weight | 350g |
Language | Chinese/English |
Battery | 3.7V,3200mAh Li-ion Battery ,>10000 times(within 8 hours) |
Display | TFT 3.5 inch |
Interface | USB/RS-232 |
Storage | Basic mode: 1000 |
Software | GQC6 Quality Control Software with QC report printing functions and more extended functions. |
Operation Temperature | 0~40℃(32~104°F) |
Storage Temperature | -20~50℃(-4~122°F) |
Humidity | <85% relative humidity, no condensation |
Standard Accessories | Power Adapter, USB cable, User Manual, GQC6 software CD (except HG60S), Calibration Plate |
Optional Accessories | Miniature Printer |
Note | The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Gloss meter
Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
a. Connect colorimeter to the PC with USB cable.
b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.
c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".
d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".
The repeatability is an important parameter for the accuracy of the colorimeter. Threenh Technology portable colorimeter for color measurements tandard deviation ΔE*ab is within 0.03 (Measurement condition: the average value of 30 measurements on the white board at an interval of 3s after calibration). Each colorimeter can pass the qualified inspection before leaving the factory to ensure it conforms to the standard of China Metrology Institute.
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.