Order No. | Name | Model | D65 | TL84 | F | UV | CWF | TL83 | Voltage |
10113 | Standard light source booth | P60(6) six light source(220V) | 2pcs | 2pcs | 4pcs | 1pcs | 2pcs | 2pcs | 220V/50Hz |
10813 | Standard light source booth | P60(6) six light source(115V) | 2pcs | 2pcs | 4pcs | 1pcs | 2pcs | 2pcs | 115V/60Hz |
Optional accessories: light source diffuser 45 degree standard stand.
Light Source | Color viewing booths application | Color temperature(k) | Power(W) |
D65 | International standard Artificial Daylight | 6500 | 18 |
TL84 | Applied to stores in Europe, Japan and China | 4000 | 18 |
CWF | (Cool White Fluorescent) American Standard | 4150 | 18 |
F/A | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
UV |
Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments |
Wave length:365nm | 20 |
TL83 | Warm White Fluorescent American Standard | 3000 | 18 |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
Threenh Technology with excellent after sale service, Generally, Our warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept. lf you have any technical problem or question with our goods welcome to contact us.
Inquiry - quotation - communication - order confirming - deposit payment - production - testing and debugging - balance payment - packing - delivery - customer receiving - after service.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
Threenh Technology colorimeter is shipped with an operating instructions and video of English version.If you need an electronic version of the user manual, you can download it from our website download center