Gray Scale Test Chart(11 steps)

This Gray Scale Test Chart(11 steps) Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

The YE0153 is designed for evaluation of the halftone reproduction of electronic cameras. Two 11-graduated counter current gray scales are arranged on a gray background (D=0.75), the gray scale being graduated logarithmically.  

Related to the densities of the gray scales: gamma = 0.45

Related to the reflectance values (brightness): gamma = 2.2 , that being exactly the reciprocal value of gamma = 0.45.

The output signal of an optimally gamma-corrected camera yield two 11-graduates counter current linear step signals. The contrast range of the gray scales is 40 : 1.

The values of the 11-graduated gray scale are as follows:

 
Step Density Reflectance in %
1 0.05 89
2 0.13 74
3 0.22 60
4 0.32 48
5 0.43 37
6 0.55 28
7 0.69 20
8 0.88 13
9 1.06 8
10 1.31 5
11 1.65 2

The density values are based on BaSo4 = 0. Two black fields and a white field are located between the gray scales, the density of the black filed is D > 2.4 (reflectance < 0.5 %). The density of the white filed is D = 0.05 (reflectance = 89.9 %).

12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

FAQs About Grayscale Charts

D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries. 

a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

Now our testing machines have been sold to more than 80 countries, like USA, Canada, Russia,UK, Italy, Germany, European , India, Pakistan, Philippine, Singapore, Malaysia,Thailand , Vietnam, Korea,Saudi Arabia,Brazil...and so on. We sell to the global market.

There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)

a. Turning on

b. Removing measuring aperture, install the needed measuring aperture.

c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.

d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.

e. Replace completed.

a. It’s needed to perform manual calibration for NH300 when first starting.

b. In the subsequent starting, no need to perform manual calibration.

c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.

Related Grayscale Charts You May Also Like