Spectrocolorimeter PS2030

High-precision Portable Color Difference Meter

The PS2030 is a compact, handheld intelligent digital display spectrocolorimeter; PS2030 is designed for precision and portability, can accurately measure samples of various shapes and sizes, suitable for plastic electronics, paint ink, textile and garment printing, printing, ceramics industries, delivering high-accuracy color measurement results.


Key Highlights

  • D/8 optical structure and SCI/SCE mode

  • 400~700nm full waveband balanced LED light source

  • CMOS dual beam splitting sensor

  • Automatic whiteboard calibration

  • Multiple color measurement spaces

  • Reliable repeatability (ΔEab ≤0.04) and inter-instrument agreement (ΔEab ≤0.4)

  • 2.8 inch TFT Capacitive Touch Screen

This PS2030 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

 "Fat girl" is the nickname of PS20 series domestic color spectrometer. It is serious about color measurement and high user satisfaction.

PS2030 "Fat girl" spectrocolorimeter is 3nh developed by CMOS dual-channel spectrocolorimeter sensor, which is not only a colorimeter, but also a spectrocolorimeter , with excellent repeatability and the inner-instrument error. The measurement data is stable, accurate and reliable. with a comfortable and round appearance more people love it. It also has quality management software facilitate quality monitoring and data management.

 

 PS2030 spectrocolorimeter is equipped with double apertures: Φ8mm/Φ10mm flat and tip, widely used for plastic electronics, paint ink, textile and garment printing, printing, ceramics and other industries color difference quality control.

 

Technical Advantages 

Adopt D/8 optical structure and SCI/SCE mode

PS2030 spectrocolorimeter adopts D/8(diffused illumination, 8-degree viewing angle) which is widely applicable in the world, and SCI/SCE (specular component included/specular component excluded) Synthesis technology. It is suitable for color management and quality control in various industries such as color matching and coating, textile, plastic, food, building materials, cosmetics, etc.

integrating_sphere.png


Adopt full waveband balanced LED light source

The 400~700nm full waveband balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of white LED in specific waveband, Fluorescent materials can also be easily measured and ensures the measurement speed and accuracy of the measurement results.

full waveband balanced LED spectrum distribution


CMOS dual beam splitting sensor


High speed and high sensitivity CMOS dual beam splitter sensor makes color data processing more efficient and accurate.

PS2030 CMOS dual beam splitting sensor



Contact automatic whiteboard calibration

The spectrocolorimeter PS2030 is equipped with an intelligent calibration base. Contact automatic whiteboard calibration is available, professional standard whiteboard reflectivity R%≥95%, good surface uniformity. It has high stability and can obtain repeated and accurate data.

PS2030 intelligent calibration base


Multiple color measurement spaces, multiple illumination source

The spectrocolorimeter PS2030 support CIE LAB,XYZ,Yxy, LCh, CIE LUV,S- RGB, βxy, DIN Lab99 Color space and D65, A, C, D50, D55, D75, F1, F2(CWF) ,F3, F4  F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), U35, NBF, ID50, ID65 multiple illumination source, Meet different measurement requirements.

ps2030 color measurement spaces illumination source




Ergonomic design and easy measurement

The fitted palm is suitable for continuous detection, which makes you fast and easy to use. An easy to measure device for automatic measurement is added. Which is portable, fast, easy to measure and use.

ps2030 Ergonomic design



Calibration Certificate

Each PS2030 spectrocolorimeter has been verified and tested. After leaving the factory, each instrument is verified according to the measurement standards of authoritative verification departments, and the measurement data are traceable to the National Metro technical Institute to ensure the authority of the instrument test data.

South China National Metrology Test Center


Color management software

SQCX quality management software with PS2030 spectrocolorimeter is suitable for quality monitoring and color data management in various industries. Data the user's color management, compare color differences, generate test reports, provide multiple color space measurement data, and customize the customer's color management.

PS2030 SQCX quality management software


 


Technical Specification


Model PS2030 spectrocolorimeter
Optical Geometry D/8(diffused illumination, 8-degree viewing angle), SCI/SCE (specular component included/specular component excluded) Mode, Comply to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
Characteristic Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries.
Light Source Combined full spectrum LED light source
Integrating Sphere Size Φ40mm
Sensor CMOS dual beam splitting sensor
Wavelength Range 400-700nm
Measuring Aperture Two Apertures:MAV:Φ8mm/Φ10mm
Specular Component SCI/SCE
Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula ΔE*ab,ΔE*uv,ΔE*94 ,ΔE*cmc(2:1),ΔE*cmc(1:1) ,ΔE*00, DINΔE99, ΔE(Hunter)
Other Colorimetric Index Spectral reflectance, WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Metamerism Index Mt,Staining Fastness, Color Fastness,Color Strength, Opacity,555 tone classification, Munsell(C/2)(Partially realize through the PC software /APP software)
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30),U35,NBF,ID50,ID65(Partially realize through the PC software /APP software)
Display Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset
Measuring Time About 1s
Repeatability Chromaticity value: MAV/SCI, within ΔE*ab 0.035 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400nm to 700nm: within 0.2%)
Inter-instrument Error MAV/SCI, Within ΔE*ab 0.35
(Average for 12 BCRA Series II color tiles)
Displayed Accuracy 0.01
Measured Reflectance   Range 0-200%
Reflectance Resolution 0.01%
Measurement Mode Single Measurement, Average Measurement(2-99times)
Locating Method Stabilizer position
White Calibration mode Contact type automatic calibration
Dimension  94X68X188mm
Weight About 410g
Battery Lithium battery,3.7V,5000mAh,8000 cycles in 8 hours
Illuminant Life Span More than 1.2 million measurements over 10 years
Screen 2.8 inch TFT true color, Capacitive Touch Screen
Interface USB
Data Storage Standard 500Pcs, Sample 5000Pcs(One data is able to include SCI/SCE);PC mass storage
Software support Windows
Language Simplified Chinese, English, Traditional Chinese
Operating Environment 0~40℃, 0~85%RH (no condensing),Altitude < 2000m
Storage Environment   -20~50℃, 0~85%RH (no condensing)
Standard Accessory Power Adapter, USB Cable, User Guide, SQCX PC Software(Download from   office website), White and Black Calibration Cavity, Protective Cover, Wrist     strap, Aperture
Optional Accessory USB Micro Printer, Powder Test Box
Notes Technical parameters are only for reference, subject to the actual sale of the  product


12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

Our Valued Clients

FAQs About Spectrocolorimeter

Yes, we can offer Spectrodensitometer quality certification issued by our lab free of charge, or issued by third-party international inspection Organizations with extra charge, please contact us for confirmation.

Yes, we offer free samples for test, you are welcome to order samples to experience our excellent quality and service.

Threenh colorimters are used across various industries to measure, analyze, and control color accuracy and consistency:

Food and Beverages: Monitor color quality in food products to meet industry standards.

Plastics and Polymers: Ensure color uniformity in plastic components (e.g., casings, buttons, panels) during manufacturing.

Chemicals and Pharmaceuticals,Cosmetics: Industry-specific accessories to attain the highest safety protocols, Ensure uniform color in pharmaceutical products for quality and brand recognition;Develop and match colors for cosmetics (e.g., lipsticks, creams, powders) and ensure batch consistency.

Textiles and Apparel: Monitor color consistency in fabrics during dyeing, printing, or finishing processes; ensure color consistency in fabrics and garments.

Building materials, Paints, and Coatings: Detect color deviations in coatings on metal, wood, or plastic surfaces (e.g., automotive paints, furniture finishes). Maintain color accuracy in building materials, paints, and coatings.

Printing and Packaging: Validate color accuracy in printed materials (e.g., brochures, labels, packaging) against design proofs, maintain consistency across different printing technologies.

By addressing color-related quality control challenges, 3NH colorimeters help industries maintain brand consistency, meet regulatory standards, and enhance customer satisfaction.


a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.

b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.

c. Turn off CQCS3 software, and reopen it.

Related Spectrocolorimeter You May Also Like